{"product_id":"pedrollo-tex-vortex-for-dirty-water-with-adjustable-float-switch-single-phase-2300200","title":"Pedrollo TEX-VORTEX For Dirty Water With Adjustable Float Switch (Single-Phase) | 2300200","description":"\u003ch4\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003eThis product is delivered directly from the supplier, lead times vary.\u003c\/span\u003e\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003eThe Pedrollo TEX® VORTEX Submersible Pump is a high-performance sewage and dirty water pump designed for the efficient removal of wastewater, greywater, flood water, and liquids containing suspended solids. Featuring an advanced VORTEX impeller, robust construction, and an innovative integrated magnetic float switch, the TEX range delivers dependable operation in both permanent and portable drainage installations. Ideal for use in pump chambers, septic systems, sewage pits, flooded basements, sumps, reservoirs, tanks, and drainage applications, the TEX VORTEX pump combines compact dimensions with impressive pumping performance, making it particularly suitable for installations where space is limited.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cp\u003eThe TEX VORTEX pump is engineered to move wastewater efficiently while maintaining low energy consumption. Its wide side discharge outlet and enlarged solids clearance reduce the risk of blockages when handling dirty water and sewage effluent. The oversized motor helps prevent overheating and ensures reliable operation even under demanding conditions.\u003c\/p\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cmeta content=\"text\/html; charset=us-ascii\" http-equiv=\"Content-Type\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDomestic sewage pumping\u003c\/li\u003e\n\u003cli\u003eWastewater transfer\u003c\/li\u003e\n\u003cli\u003eDirty water drainage\u003c\/li\u003e\n\u003cli\u003eSeptic tank pumping stations\u003c\/li\u003e\n\u003cli\u003eBasement flood protection\u003c\/li\u003e\n\u003cli\u003eCellar drainage\u003c\/li\u003e\n\u003cli\u003eSump and pit emptying\u003c\/li\u003e\n\u003cli\u003eTanks and reservoirs\u003c\/li\u003e\n\u003cli\u003eSurface water management\u003c\/li\u003e\n\u003cli\u003eEmergency dewatering applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/div\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cstyle\u003e\na {\n    text-decoration: none;\n    color: #464feb;\n}\ntr th, tr td {\n    border: 1px solid #e6e6e6;\n}\ntr th {\n    background-color: #f5f5f5;\n}\n\u003c\/style\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cdiv class=\"___5wvz9a0 ftgm304 f1oy3dpc fm6nont f48hbct\" role=\"group\" aria-label=\"Table\" data-stable-ignore=\"true\" data-tabster='{\"restorer\":{\"type\":1}}' aria-expanded=\"false\" data-fui-focus-visible=\"\" tabindex=\"0\"\u003e\n\u003cdiv class=\"___1dmoc29 f10pi13n ftgm304 f1enuhaj fdclmfp f1nbblvp fat0sn4 f1ov4xf1 fekwl8i f1lmfglv f1oz7aqm f1abmfm4 f1w619qj f16h0jq8\" role=\"group\" aria-label=\"Table content\"\u003e\n\u003ctable class=\"___nvz3nv0 f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 f1y24664 f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eTEX 2\u003c\/th\u003e\n\u003cth\u003eTEX 3\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Output (P2)\u003c\/td\u003e\n\u003ctd\u003e0.37 kW\u003c\/td\u003e\n\u003ctd\u003e0.55 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHorsepower\u003c\/td\u003e\n\u003ctd\u003e0.50 HP\u003c\/td\u003e\n\u003ctd\u003e0.75 HP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e240 l\/min (14.4 m³\/h)\u003c\/td\u003e\n\u003ctd\u003e240 l\/min (14.4 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Head\u003c\/td\u003e\n\u003ctd\u003e8 m\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Solids Handling\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage (Single Phase)\u003c\/td\u003e\n\u003ctd\u003e220V\u003c\/td\u003e\n\u003ctd\u003e220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw @ 220V\u003c\/td\u003e\n\u003ctd\u003e2.3A\u003c\/td\u003e\n\u003ctd\u003e3.7A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Connection\u003c\/td\u003e\n\u003ctd\u003e1¼\"\u003c\/td\u003e\n\u003ctd\u003e1¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHose Connector\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003ctd\u003e40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloat Switch\u003c\/td\u003e\n\u003ctd\u003eMagnetic Vertical Float\u003c\/td\u003e\n\u003ctd\u003eMagnetic Vertical Float\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Submersion Depth\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e6.1 kg\u003c\/td\u003e\n\u003ctd\u003e7.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cdiv class=\"___5wvz9a0 ftgm304 f1oy3dpc fm6nont f48hbct\" role=\"group\" aria-label=\"Table\" data-stable-ignore=\"true\" data-tabster='{\"restorer\":{\"type\":1}}' aria-expanded=\"false\" data-fui-focus-visible=\"\" tabindex=\"0\"\u003e\n\u003cdiv class=\"___1dmoc29 f10pi13n ftgm304 f1enuhaj fdclmfp f1nbblvp fat0sn4 f1ov4xf1 fekwl8i f1lmfglv f1oz7aqm f1abmfm4 f1w619qj f16h0jq8\" role=\"group\" aria-label=\"Table content\"\u003e\n\u003ctable class=\"___nvz3nv0 f1ddd56o f16vktn6 f1ahpp82 f11qra4b f1uinfot fibjyge fvueend f9yszdx f1fu4s3n f3l3pb3 f10ghnd0 f8fmt76 fjvbh62 f1qrqxae f1vw5qpk fc02sbz fxawf59 fymf513 f1aoyrul f1el8yx3 f1pymoxg f1ofu761 f1y24664 f7coize f1794535 f1o0pw0q fbjjl9v fk1v6el f16pyhcb f1ixlhx9 f12zef0i flu5r5u f19haqzy f1owmcxx f1oddm8q f1004tna fcoaxci fh0ee9u f15v23i2 f1dmj53 f1r1gcv9 f14z1veh ffufd3x f1ypplot f1660cg\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Type\u003c\/td\u003e\n\u003ctd\u003eSubmersible VORTEX Sewage Pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e240 l\/min (14.4 m³\/h)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Head\u003c\/td\u003e\n\u003ctd\u003e10 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Solids Passage\u003c\/td\u003e\n\u003ctd\u003e30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Submersion Depth\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Liquid Temperature\u003c\/td\u003e\n\u003ctd\u003e+40°C Continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Term Temperature\u003c\/td\u003e\n\u003ctd\u003eUp to +90°C (3 minutes max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Drainage Level\u003c\/td\u003e\n\u003ctd\u003e35 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloat Switch\u003c\/td\u003e\n\u003ctd\u003eMagnetic Vertical Float\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDischarge Connection\u003c\/td\u003e\n\u003ctd\u003e1¼\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHose Connector\u003c\/td\u003e\n\u003ctd\u003eØ40 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Cable Length\u003c\/td\u003e\n\u003ctd\u003e5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInsulation Class\u003c\/td\u003e\n\u003ctd\u003eF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIPX8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 99.9828%; height: 39.1666px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 6.01446%; height: 19.5833px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\" width=\"30\" height=\"37\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 93.7581%; height: 19.5833px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/TEX_EN-datasheet_60Hz.pdf?v=1794993720\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003eData Sheet\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5833px;\"\u003e\n\u003ctd style=\"width: 6.01446%; height: 19.5833px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\" width=\"30\" height=\"37\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 93.7581%; height: 19.5833px;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/120399202E01_00-26_f48f9f8c-ea08-4031-8a56-c285249612d9.pdf?v=1794993814\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003eInstallation Guide\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e","brand":"Pedrollo","offers":[{"title":"TEX 2 | 2300200","offer_id":57787819786613,"sku":null,"price":325.0,"currency_code":"GBP","in_stock":true},{"title":"TEX 3 | 2300210","offer_id":57787819819381,"sku":null,"price":339.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/TEX-600x600.webp?v=1794994426","url":"https:\/\/direct-drainage.co.uk\/products\/pedrollo-tex-vortex-for-dirty-water-with-adjustable-float-switch-single-phase-2300200","provider":"Direct Drainage","version":"1.0","type":"link"}