{"title":"Klargester Full Retention Separators","description":"\u003cp\u003eKlargester Full Retention separators are engineered for high‑risk areas such as roadways, fuel depots, car parks, and vehicle workshops, providing complete treatment of surface water flow during heavy rainfall events. Certified to EN858‑1 and designed for easy installation, these robust GRP or PE units reliably remove oil and silt to meet strict environmental standards. With fitted inlet\/outlet connections, vent points, and optional oil alarm systems, they offer durable, low‑maintenance performance ideal for commercial and industrial sites requiring dependable pollution control.\u003c\/p\u003e","products":[{"product_id":"klargester-nsfa050-full-retention-separator","title":"2780m2 Clearwater  Full Retention Separator | NSFA050","description":"\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for easy installation\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eOil alarm probe tube available (required by EN858-1 and PPG3)\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eVent points within necks\u003c\/li\u003e\n\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\u003cli\u003eHigh strength and durability\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFitted inlet\/ outlet connections\u003c\/li\u003e\n\u003cli\u003eCertified to EN858 - 1 and PPG3\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%; height: 195.938px;\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.7669%; height: 19.5938px;\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%; height: 19.5938px;\"\u003eNSFA050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.7669%; height: 19.5938px;\"\u003e\u003cstrong\u003eFlow (l\/s)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%; height: 19.5938px;\"\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.7669%; height: 19.5938px;\"\u003e\u003cstrong\u003eDrainage Area (m²) \u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%; height: 19.5938px;\"\u003e2780\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.7669%; height: 19.5938px;\"\u003e\u003cstrong\u003eStorage Capacity (L) Silt\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%; height: 19.5938px;\"\u003e5000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.7669%; height: 19.5938px;\"\u003e\u003cstrong\u003eStorage Capacity (L) Oil\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%; height: 19.5938px;\"\u003e500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.7669%; height: 19.5938px;\"\u003e\u003cstrong\u003eLength (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%; height: 19.5938px;\"\u003e5425\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.7669%; height: 19.5938px;\"\u003e\n\u003cstrong\u003eManhole Cover Dimensions (mm)\u003c\/strong\u003e\u003cbr\u003e\n\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%; height: 19.5938px;\"\u003e600\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.7669%; height: 19.5938px;\"\u003e\u003cstrong\u003eBase Inlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%; height: 19.5938px;\"\u003e1810\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.7669%; height: 19.5938px;\"\u003e\u003cstrong\u003eBase to Outlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%; height: 19.5938px;\"\u003e1760\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 47.7669%;\"\u003e\u003cstrong\u003eMin Inlet Invert (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%;\"\u003e1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 19.5938px;\"\u003e\n\u003ctd style=\"width: 47.7669%; height: 19.5938px;\"\u003e\u003cstrong\u003eStandard Pipework Diameter (mm)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 51.8721%; height: 19.5938px;\"\u003e 315\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"Default Title","offer_id":31777093877849,"sku":"TANSEPACLE021","price":6023.23,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa065-full-retention-separator","title":"3610m2 Clearwater Full Retention Separator | NSFA065","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch1\u003eClearwater Full Retention Separator\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003efree delivery!\u003c\/p\u003e\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"Default Title","offer_id":31777093910617,"sku":"TANSEPAKLA061","price":6646.73,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa080-full-retention-separator","title":"4445m2 Clearwater Full Retention Separator | NSFA080","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch1\u003eClearwater NSFA080 Full Retention Separator\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003efree delivery!\u003c\/p\u003e\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"Default Title","offer_id":31777093976153,"sku":"TANSEPAKLA062","price":9317.02,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa100-full-retention-separator","title":"5560m2 Clearwater Full Retention Separator | NSFA100","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch1\u003eClearwater NSFA100 Full Retention Separator\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003efree delivery!\u003c\/p\u003e\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"Default Title","offer_id":31777094008921,"sku":"TANSEPAKLA063","price":9621.25,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa125-full-retention-separator","title":"6945m2 Clearwater  Full Retention Separator | NSFA125","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch1\u003eClearwater NSFA125 Full Retention Separator\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003efree delivery!\u003c\/p\u003e\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"Default Title","offer_id":31777094041689,"sku":"TANSEPAKLA064","price":10249.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa150-full-retention-separator","title":"8335m2 Clearwater  Full Retention Separator | NSFA150","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch1\u003eClearwater NSFA150 Full Retention Separator\u003c\/h1\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003efree delivery!\u003c\/p\u003e\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"Default Title","offer_id":31777094074457,"sku":"TANSEPAKLA065","price":11503.58,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa175-full-retention-separator","title":"9725m2 Clearwater Full Retention Separator | NSFA175","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch1\u003eClearwater NSFA175 Full Retention Separator\u003c\/h1\u003e\n\u003cp\u003efree delivery!\u003c\/p\u003e\n\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"Default Title","offer_id":31777094139993,"sku":"TANSEPAKLA066","price":13598.75,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa200-full-retention-separator","title":"11110m2 Clearwater Full Retention Separator | NSFA200","description":"\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"Default Title","offer_id":31777094205529,"sku":"TANSEPAKLA067","price":14330.83,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa010-full-retention-oil-separator-555m2","title":"555m2 Clearwater  Full Retention Oil Separator | NSFA010","description":"\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/nsfa015-full-retention-separators.pdf?v=1680689410\" title=\"nsfa015-full-retention-separators\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_50x50.png?v=1595254149\" alt=\"\" data-mce-fragment=\"1\"\u003e Clearwater NSFA010 – NSFA015 Full Retention Separator Installation \u0026amp; Operation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/nsfa010-015-full-retention-separators.pdf?v=1680689498\" title=\"NSFA010 Drawing\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_50x50.png?v=1595254149\" alt=\"\" data-mce-fragment=\"1\"\u003eNSFA 010 Drawing\u003c\/a\u003e\u003cbr\u003e \u003cbr\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems. \u003cbr\u003e \u003c\/p\u003e\n\u003ch2\u003e\u003cspan style=\"color: #000000;\"\u003eClearwater NSFA010 Alarm Options\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eEnvironment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase the \u003ca style=\"color: #000000;\" href=\"http:\/\/direct-drainage.co.uk\/product\/darcy-mains-separator-alarm-with-high-oil-probe-indoor-install-only\/?attribute_pa_type-of-alarm=mains-alarm-with-junction-box\" title=\"Darcy Indoor Mains Alarm\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDarcy Indoor Mains Alarm\u003c\/span\u003e\u003c\/a\u003e or \u003ca style=\"color: #000000;\" href=\"http:\/\/direct-drainage.co.uk\/product\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\/\" title=\"Darcy Outdoor Oil Alarm\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eDarcy Outdoor Mains Alarm\u003c\/span\u003e\u003c\/a\u003e alongside this item, and it will be delivered with the separator ready to wire in.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\n\u003cspan style=\"color: #000000;\"\u003eClearwater NSFA010 \u003c\/span\u003e\u003cspan style=\"color: #000000;\"\u003eFeatures and Benefits\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eLight and easy to install\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eInclusive of silt storage volume\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eFitted inlet\/outlet connectors\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eVent points within necks\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eExtension access shafts for deep inverts\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eMaintenance from ground level\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan style=\"color: #000000;\"\u003eGRP or rotomoulded construction (rotomoulded for NSFP003 and NSFP006)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cbr\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGarage Forecourts\u003c\/li\u003e\n\u003cli\u003eCar Parks\u003c\/li\u003e\n\u003cli\u003eWorkshops\u003c\/li\u003e\n\u003cli\u003eSupermarket \/ Shopping Centres\u003c\/li\u003e\n\u003cli\u003eDistribution Warehouses\u003c\/li\u003e\n\u003cli\u003eCar Wash Bays\u003c\/li\u003e\n\u003cli\u003eScrap Yards\u003c\/li\u003e\n\u003cli\u003eCar Garages\u003c\/li\u003e\n\u003cli\u003eFuel Storage Sites\u003c\/li\u003e\n\u003cli\u003eDistribution\/Haulage Centres\u003c\/li\u003e\n\u003cli\u003eWaste Transfer Sites\u003c\/li\u003e\n\u003cli\u003eBusiness\/Commercial Parks\/Industrial Estates\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Clearwater","offers":[{"title":"No","offer_id":31777120616537,"sku":"TANSEPAKLA024","price":1892.0,"currency_code":"GBP","in_stock":true},{"title":"Yes","offer_id":56574398726517,"sku":null,"price":2230.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa015-full-retention-oil-separator-835m2","title":"835m2 Clearwater Full Retention Oil Separator | NSFA015","description":"\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems.  \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eClearwater NSFA015 Alarm Options\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003cspan\u003eEnvironment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase the \u003ca href=\"http:\/\/direct-drainage.co.uk\/product\/darcy-mains-separator-alarm-with-high-oil-probe-indoor-install-only\/?attribute_pa_type-of-alarm=mains-alarm-with-junction-box\" title=\"Darcy Indoor Mains Alarm\" target=\"_blank\"\u003eDarcy Indoor Mains Alarm\u003c\/a\u003e or \u003ca href=\"http:\/\/direct-drainage.co.uk\/product\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\/\" title=\"Darcy Outdoor Oil Alarm\" target=\"_blank\"\u003eDarcy Outdoor Mains Alarm\u003c\/a\u003e alongside this item, and it will be delivered with the separator ready to wire in.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch2\u003e\n\u003cspan\u003eClearwater NSFA015 \u003c\/span\u003e\u003cspan\u003eFeatures and Benefits\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight and easy to install\u003c\/li\u003e\n\u003cli\u003eInclusive of silt storage volume\u003c\/li\u003e\n\u003cli\u003eFitted inlet\/outlet connectors\u003c\/li\u003e\n\u003cli\u003eVent points within necks\u003c\/li\u003e\n\u003cli\u003eExtension access shafts for deep inverts\u003c\/li\u003e\n\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\u003cli\u003eGRP or rotomoulded construction (rotomoulded for NSFP003 and NSFP006)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\n\u003cbr\u003e\u003cbr\u003eApplications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eGarage Forecourts\u003c\/li\u003e\n\u003cli\u003eCar Parks\u003c\/li\u003e\n\u003cli\u003eWorkshops\u003c\/li\u003e\n\u003cli\u003eSupermarket \/ Shopping Centres\u003c\/li\u003e\n\u003cli\u003eDistribution Warehouses\u003c\/li\u003e\n\u003cli\u003eCar Wash Bays\u003c\/li\u003e\n\u003cli\u003eScrap Yards\u003c\/li\u003e\n\u003cli\u003eCar Garages\u003c\/li\u003e\n\u003cli\u003eFuel Storage Sites\u003c\/li\u003e\n\u003cli\u003eDistribution\/Haulage Centres\u003c\/li\u003e\n\u003cli\u003eWaste Transfer Sites\u003c\/li\u003e\n\u003cli\u003eBusiness\/Commercial Parks\/Industrial Estates\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Clearwater","offers":[{"title":"No","offer_id":31777120747609,"sku":"TANSEPAKLA026","price":2185.47,"currency_code":"GBP","in_stock":true},{"title":"Yes","offer_id":56574518460789,"sku":null,"price":2524.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa020-full-retention-oil-separator-1115m2","title":"1115m2 Clearwater  Full Retention Oil Separator | NSFA020","description":"\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems. \u003cspan\u003eEnvironment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase the \u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/direct-drainage.co.uk\/product\/darcy-mains-separator-alarm-with-high-oil-probe-indoor-install-only\/?attribute_pa_type-of-alarm=mains-alarm-with-junction-box\" title=\"Darcy Indoor Mains Alarm\" style=\"color: rgb(255, 128, 0);\" target=\"_blank\"\u003eDarcy Indoor Mains Alarm\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e or \u003ca href=\"http:\/\/direct-drainage.co.uk\/product\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\/\" title=\"Darcy Outdoor Oil Alarm\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0); text-decoration: underline;\"\u003e\u003cstrong\u003eDarcy Outdoor Mains Alarm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e alongside this item, and it will be delivered with the separator ready to wire in.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch3\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h3\u003e\n\u003ch4\u003e\u003cspan\u003eBenefits\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLight and easy to install\u003c\/li\u003e\n\u003cli\u003eInclusive of silt storage volume\u003c\/li\u003e\n\u003cli\u003eFitted inlet\/outlet connectors\u003c\/li\u003e\n\u003cli\u003eVent points within necks\u003c\/li\u003e\n\u003cli\u003eExtension access shafts for deep inverts\u003c\/li\u003e\n\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\u003cli\u003eGRP or rotomoulded construction (rotomoulded for NSFP003 and NSFP006)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cbr\u003e\u003cbr\u003eApplications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGarage Forecourts\u003c\/li\u003e\n\u003cli\u003eCar Parks\u003c\/li\u003e\n\u003cli\u003eWorkshops\u003c\/li\u003e\n\u003cli\u003eSupermarket \/ Shopping Centres\u003c\/li\u003e\n\u003cli\u003eDistribution Warehouses\u003c\/li\u003e\n\u003cli\u003eCar Wash Bays\u003c\/li\u003e\n\u003cli\u003eScrap Yards\u003c\/li\u003e\n\u003cli\u003eCar Garages\u003c\/li\u003e\n\u003cli\u003eFuel Storage Sites\u003c\/li\u003e\n\u003cli\u003eDistribution\/Haulage Centres\u003c\/li\u003e\n\u003cli\u003eWaste Transfer Sites\u003c\/li\u003e\n\u003cli\u003eBusiness\/Commercial Parks\/Industrial Estates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"No","offer_id":31777120845913,"sku":"TANSEPAKLA027","price":3432.47,"currency_code":"GBP","in_stock":true},{"title":"Yes","offer_id":56574573085045,"sku":null,"price":3771.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa030-full-retention-oil-separator-1670m2","title":"1670m2 Clearwater Full Retention Oil Separator | NSFA030","description":"\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems. \u003cspan\u003eEnvironment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase the \u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003ca title=\"Darcy Indoor Mains Alarm\" href=\"http:\/\/direct-drainage.co.uk\/product\/darcy-mains-separator-alarm-with-high-oil-probe-indoor-install-only\/?attribute_pa_type-of-alarm=mains-alarm-with-junction-box\" style=\"color: rgb(255, 128, 0);\" target=\"_blank\"\u003e\u003cstrong\u003eDarcy Indoor Mains Alarm\u003c\/strong\u003e\u003c\/a\u003e \u003c\/span\u003eor \u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003ca title=\"Darcy Outdoor Oil Alarm\" href=\"http:\/\/direct-drainage.co.uk\/product\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\/\" style=\"color: rgb(255, 128, 0);\" target=\"_blank\"\u003e\u003cstrong\u003eDarcy Outdoor Mains Alarm\u003c\/strong\u003e\u003c\/a\u003e \u003c\/span\u003ealongside this item, and it will be delivered with the separator ready to wire in.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch5\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/h5\u003e\n\u003ch4\u003e\u003cspan\u003eFeatures and Benefits\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLight and easy to install\u003c\/li\u003e\n\u003cli\u003eInclusive of silt storage volume\u003c\/li\u003e\n\u003cli\u003eFitted inlet\/outlet connectors\u003c\/li\u003e\n\u003cli\u003eVent points within necks\u003c\/li\u003e\n\u003cli\u003eExtension access shafts for deep inverts\u003c\/li\u003e\n\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\u003cli\u003eGRP or rotomoulded construction (rotomoulded for NSFP003 and NSFP006)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cbr\u003eApplications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGarage Forecourts\u003c\/li\u003e\n\u003cli\u003eCar Parks\u003c\/li\u003e\n\u003cli\u003eWorkshops\u003c\/li\u003e\n\u003cli\u003eSupermarket \/ Shopping Centres\u003c\/li\u003e\n\u003cli\u003eDistribution Warehouses\u003c\/li\u003e\n\u003cli\u003eCar Wash Bays\u003c\/li\u003e\n\u003cli\u003eScrap Yards\u003c\/li\u003e\n\u003cli\u003eCar Garages\u003c\/li\u003e\n\u003cli\u003eFuel Storage Sites\u003c\/li\u003e\n\u003cli\u003eDistribution\/Haulage Centres\u003c\/li\u003e\n\u003cli\u003eWaste Transfer Sites\u003c\/li\u003e\n\u003cli\u003eBusiness\/Commercial Parks\/Industrial Estates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"No","offer_id":31777120944217,"sku":"TANSEPAKLA028","price":4039.85,"currency_code":"GBP","in_stock":true},{"title":"Yes","offer_id":56574673191285,"sku":null,"price":4378.48,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfa040-full-retention-oil-separator-2225m2","title":"2225m2 Clearwater Full Retention Oil Separator | NSFA040","description":"\u003cp\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr. On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems. \u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eEnvironment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase the \u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/direct-drainage.co.uk\/product\/darcy-mains-separator-alarm-with-high-oil-probe-indoor-install-only\/?attribute_pa_type-of-alarm=mains-alarm-with-junction-box\" title=\"Darcy Indoor Mains Alarm\" style=\"color: rgb(255, 128, 0);\" target=\"_blank\"\u003eDarcy Indoor Mains Alarm\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e or \u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca href=\"http:\/\/direct-drainage.co.uk\/product\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\/\" title=\"Darcy Outdoor Oil Alarm\" style=\"color: rgb(255, 128, 0);\" target=\"_blank\"\u003eDarcy Outdoor Mains Alarm\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e alongside this item, and it will be delivered with the separator ready to wire in.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan\u003eFeatures and Benefits\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eLight and easy to install\u003c\/li\u003e\n\u003cli\u003eInclusive of silt storage volume\u003c\/li\u003e\n\u003cli\u003eFitted inlet\/outlet connectors\u003c\/li\u003e\n\u003cli\u003eVent points within necks\u003c\/li\u003e\n\u003cli\u003eExtension access shafts for deep inverts\u003c\/li\u003e\n\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\u003cli\u003eGRP or rotomoulded construction (rotomoulded for NSFP003 and NSFP006)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\n\u003cbr\u003eApplications\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGarage Forecourts\u003c\/li\u003e\n\u003cli\u003eCar Parks\u003c\/li\u003e\n\u003cli\u003eWorkshops\u003c\/li\u003e\n\u003cli\u003eSupermarket \/ Shopping Centres\u003c\/li\u003e\n\u003cli\u003eDistribution Warehouses\u003c\/li\u003e\n\u003cli\u003eCar Wash Bays\u003c\/li\u003e\n\u003cli\u003eScrap Yards\u003c\/li\u003e\n\u003cli\u003eCar Garages\u003c\/li\u003e\n\u003cli\u003eFuel Storage Sites\u003c\/li\u003e\n\u003cli\u003eDistribution\/Haulage Centres\u003c\/li\u003e\n\u003cli\u003eWaste Transfer Sites\u003c\/li\u003e\n\u003cli\u003eBusiness\/Commercial Parks\/Industrial Estates\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"No","offer_id":31777121042521,"sku":"TANSEPAKLA029","price":5052.5,"currency_code":"GBP","in_stock":true},{"title":"Yes","offer_id":56574710481269,"sku":null,"price":5391.12,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Forecourt_Cutaway_web_2.png?v=1742811569"},{"product_id":"klargester-nsfp003-full-retention-oil-separator-170m2","title":"170m2 Klargester Full Retention Oil Separator | NSFP003","description":"\u003cp\u003eThe Kingspan Klargester NSFP003 is designed to handle a 170m2 drainage area and is suitable for use in car parks, roadways, fuel distribution depots, vehicle workshops and forecourts. Full retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr.  On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems. The Klargester NSFP003 offers  total satisfaction. An oil alarm probe tube is included, and it incorporates convenient inlet\/outlet connections, vent points and is designed for maintenance from the ground level. Available in GRP or rotomoulded construction, the product is CE-marked.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 5.98762%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\" width=\"32\" height=\"40\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 93.6514%;\"\u003e \u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Full-Retention-Separator-drawing-NSFP003-NSFP006.pdf?v=1640276472\" title=\"Klargester-Kingspan-Full-Retention-Separator-drawing-NSFP003-NSFP006\" style=\"color: rgb(255, 128, 0);\"\u003eKlargester Kingspan Full Retention Separator drawing – NSFP003-NSFP006\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 5.98762%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\" width=\"32\" height=\"40\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 93.6514%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Plastic-Full-Retention-Separator-Guidelines-NSFP003-NSFP006.pdf?v=1640276473\" title=\"Klargester-Kingspan-Plastic-Full-Retention-Separator-Guidelines-NSFP003-NSFP006\" style=\"color: rgb(255, 128, 0);\"\u003eKlargester Kingspan Plastic Full Retention Separator Guidelines – NSFP003-NSFP006\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Klargester","offers":[{"title":"No","offer_id":31777139294297,"sku":"TANSEPAKLA020","price":1085.7,"currency_code":"GBP","in_stock":true},{"title":"Yes","offer_id":56574368776565,"sku":null,"price":1446.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/products-SmallSep1_73829500-ad86-4745-afda-40ac9adb277b.jpg?v=1647018639"},{"product_id":"klargester-nsfp006-full-retention-oil-separator-335m2","title":"335m2 Klargester Full Retention Oil Separator | NSFP006","description":"\u003cp\u003e\u003cstrong data-mce-fragment=\"1\"\u003e\u003c\/strong\u003eKingspan Klargester's NSFP006 Full Retention Separator is designed for a drainage area of 335m2, perfect for car parks, roadways, fuel distribution depots, vehicle workshops, and forecourts. \u003cbr\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Full-Retention-Separator-drawing-NSFP003-NSFP006.pdf?v=1640276472\" title=\"Klargester-Kingspan-Full-Retention-Separator-drawing-NSFP003-NSFP006\"\u003e\u003cspan style=\"color: #b45f06;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"36\" height=\"36\"\u003e Klargester Kingspan Full Retention Separator drawing – NSFP003-NSFP006\u003c\/span\u003e\u003c\/a\u003e\u003cbr\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Plastic-Full-Retention-Separator-Guidelines-NSFP003-NSFP006.pdf?v=1640276473\" title=\"Klargester-Kingspan-Plastic-Full-Retention-Separator-Guidelines-NSFP003-NSFP006\"\u003e\u003cspan style=\"color: #b45f06;\"\u003e\u003cimg height=\"36\" width=\"36\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\"\u003e \u003c\/span\u003eKlargester Kingspan Plastic Full Retention Separator Guidelines – NSFP003-NSFP006\u003c\/a\u003e\u003cbr\u003e \u003cbr\u003eFull retention separators treat the full flow that can be delivered by the drainage system, which is normally equivalent to the flow generated by a rainfall intensity of 65mm\/hr.  On large sites, some short term flooding may be an acceptable means of limiting the flow rate and hence the size of full retention systems.\u003cbr\u003e \u003cbr\u003eThe Klargester NSFP006 is designed for simple and efficient installation, offering savings in time and money. The product includes a fitted inlet\/outlet connection and an oil alarm probe tube. Vent points are positioned in the necks for easy maintenance, and the construction is either GRP or rotomoulded, depending on the model. Finally, the product is CE-marked.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Klargester","offers":[{"title":"No","offer_id":31777139589209,"sku":"TANSEPAKLA005","price":1287.0,"currency_code":"GBP","in_stock":true},{"title":"Yes","offer_id":56574379917685,"sku":null,"price":1644.5,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/products-SmallSep1.jpg?v=1589217103"},{"product_id":"klargester-aquatreat-full-retention-tank-swto10","title":"Klargester AquaTreat Full Retention Tank SWT010","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca title=\"Klargester Aquatreat Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" width=\"55\" height=\"55\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" title=\"AquaTreat Installation Guidelines\" rel=\"noopener noreferrer\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" title=\"AquaCore Range Brochure\" rel=\"noopener noreferrer\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" title=\"AquaTreat Extension Neck Drawing\" rel=\"noopener noreferrer\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397242826841,"sku":"SWT010","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat.png?v=1677759413"},{"product_id":"klargester-aquatreat-full-retention-tank-swt015","title":"Klargester AquaTreat Full Retention Tank SWT015","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397247938649,"sku":"SWT015","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_ebbcb75a-bcf6-4b88-9707-ef2e62e2f854.png?v=1677759518"},{"product_id":"klargester-aquatreat-full-retention-tank-swt020","title":"Klargester AquaTreat Full Retention Tank SWT020","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397248168025,"sku":"SWT020","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_40e30bc3-26f4-43e8-ab0f-d45bf4d3deb6.png?v=1677759560"},{"product_id":"copy-of-klargester-aquatreat-full-retention-tank-swt030","title":"Klargester AquaTreat Full Retention Tank SWT040","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397249249369,"sku":"SWT040","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_4c601531-9b49-4efa-b0f1-90c3471f0559.png?v=1677759581"},{"product_id":"klargester-aquatreat-full-retention-tank-swt050","title":"Klargester AquaTreat Full Retention Tank SWT050","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397250297945,"sku":"SWT050","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_c2d0022c-05cd-4dc9-be1a-ae687006f8e2.png?v=1677759602"},{"product_id":"klargester-aquatreat-full-retention-tank-swt065","title":"Klargester AquaTreat Full Retention Tank SWT065","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397251608665,"sku":"SWT065","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_29e5094d-e5bd-40c4-8008-5999150f1846.png?v=1677759620"},{"product_id":"klargester-aquatreat-full-retention-tank-swt080","title":"Klargester AquaTreat Full Retention Tank SWT080","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397253279833,"sku":"SWT080","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_3702662e-bf68-46fd-a29d-ca07ea5f7b1c.png?v=1677759642"},{"product_id":"klargester-aquatreat-full-retention-tank-swt100","title":"Klargester AquaTreat Full Retention Tank SWT100","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397254262873,"sku":"SWT100","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_024806f2-e859-43b2-8a4c-71a7dcb76a97.png?v=1677759657"},{"product_id":"klargester-aquatreat-full-retention-tank-swt125","title":"Klargester AquaTreat Full Retention Tank SWT125","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397254688857,"sku":"SWT125","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_cc6810f5-2f34-465a-82bb-80eb851341ee.png?v=1677759673"},{"product_id":"klargester-aquatreat-full-retention-tank-swt150","title":"Klargester AquaTreat Full Retention Tank SWT150","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397254754393,"sku":"SWT150","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_e1b67631-7696-4219-9314-5f65773a4981.png?v=1677759688"},{"product_id":"klargester-aquatreat-full-retention-tank-swt175","title":"Klargester AquaTreat Full Retention Tank SWT175","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397254819929,"sku":"SWT175","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_fc87ee11-5583-46c0-89eb-364902e32748.png?v=1677759703"},{"product_id":"copy-of-klargester-aquatreat-full-retention-tank-swt200","title":"Klargester AquaTreat Full Retention Tank SWT200","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397255016537,"sku":"SWT200","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_2e8be1e4-6c01-44c7-b91b-a9c1487d4968.png?v=1677759719"},{"product_id":"copy-of-copy-of-klargester-aquatreat-full-retention-tank-swt210","title":"Klargester AquaTreat Full Retention Tank SWT210","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397255213145,"sku":"SWT210","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_fd475696-6021-4879-9bd0-cb73597b1086.png?v=1677759735"},{"product_id":"klargester-aquatreat-full-retention-tank-swt225","title":"Klargester AquaTreat Full Retention Tank SWT225","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003c\/span\u003e\u003c\/a\u003e\u003ca title=\"Klargester Aquatreat Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" target=\"_blank\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" width=\"55\" height=\"55\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" title=\"AquaTreat Installation Guidelines\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" title=\"AquaCore Range Brochure\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" title=\"AquaTreat Extension Neck Drawing\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397255802969,"sku":"SWT225","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_8bc82caf-56b7-4324-ab25-72860cdac127.png?v=1677759752"},{"product_id":"klargester-aquatreat-full-retention-tank-swt240","title":"Klargester AquaTreat Full Retention Tank SWT240","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397256851545,"sku":"SWT240","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_7432ce18-9296-4a42-b2d2-7799d8305dd0.png?v=1677759767"},{"product_id":"klargester-aquatreat-full-retention-tank-swt255","title":"Klargester AquaTreat Full Retention Tank SWT255","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397257343065,"sku":"SWT255","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_b018b948-af09-4d44-8a06-c5dc8ff51641.png?v=1677759782"},{"product_id":"klargester-aquatreat-full-retention-tank-swt270","title":"Klargester AquaTreat Full Retention Tank SWT270","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397258358873,"sku":"SWT270","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_a23ca41e-1965-4372-83b2-695c2eb12a4b.png?v=1677759799"},{"product_id":"klargester-aquatreat-full-retention-tank-swt285","title":"Klargester AquaTreat Full Retention Tank SWT285","description":"\u003cp\u003eThe \u003cstrong\u003eKlargester AquaTreat\u003c\/strong\u003e range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing, suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. \u003cspan data-mce-fragment=\"1\"\u003eAquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight \u0026amp; easy to install\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eEasier servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\"\u003e\u003cimg height=\"55\" width=\"55\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"56\" height=\"56\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaCore Range Brochure\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\" data-mce-href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"56\" width=\"56\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" data-mce-src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\"\u003eAquaTreat Extension Neck Drawing\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":40397258817625,"sku":"SWT285","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat_5777337f-abe9-4229-bfc4-7a541c73607a.png?v=1677759815"},{"product_id":"spel-puraceptors-full-retention-forecourt-seperators","title":"SPEL Puraceptor Full Retention Forecourt Seperator 7600 litres","description":"\u003cp\u003eThe SPEL FP1C\/SC Forecourt Separator is a fully BS EN 858 (the oil separator British Standard) compliant unit designed specifically for petrol filling stations. It is a full retention oil separator and therefore comes with our high quality, long life Automatic Closure Device (ACD) that will close off the whole system in the case of a catastrophic spill, protecting you and your reputation, as well as the environment. It comes with enough oil storage capacity to contain one compartment of a road tanker in the event of a catastrophic loss – 7,600 litres.\u003c\/p\u003e\n\u003cp\u003eBS EN 858 requires an oil alarm to be fitted. A silt alarm is also recommended to avoid costly in-person maintenance checks and keep your unit in the best condition and operating correctly. \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFill in our enquiry form for a full, comprehensive and site-specific quotation turned around to you quickly. \u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/SPEL_Forecourt_Separator_Website_Enquiry_Form.pdf?v=1701253829\" title=\"SPEL Forecourt Separator Website Enquiry Form\" rel=\"noopener noreferrer\" style=\"color: rgb(255, 128, 0);\" target=\"_blank\"\u003eSPEL Forecourt Separator Website Enqu\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/SPEL_Forecourt_Separator_Website_Enquiry_Form.pdf?v=1701253829\" title=\"SPEL Forecourt Separator Website Enquiry Form\" rel=\"noopener noreferrer\" style=\"color: rgb(255, 128, 0);\" target=\"_blank\"\u003eiry Form\u003c\/a\u003e\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e25 Year Warranty and life expectancy in excess of 50 years at all depths and water table levels.\u003c\/li\u003e\n\u003cli\u003eBS EN 858 compliant to either Class I and Class II dependent on discharge requirements\u003c\/li\u003e\n\u003cli\u003eIntegral silt storage capacity\u003c\/li\u003e\n\u003cli\u003eFull working drawing supplied for approval to ensure you know what will be arriving and to ensure the correct product is supplied\u003c\/li\u003e\n\u003cli\u003eEasy access for maintenance\u003c\/li\u003e\n\u003cli\u003eOil storage volume with the capacity to contain one compartment of a road tanker in the event of a catastrophic loss – 7,600 litres.\u003c\/li\u003e\n\u003cli\u003eHigh quality, long life Automatic Closure Device (ACD) to close off the system in case of a catastrophic failure.\u003c\/li\u003e\n\u003cli\u003eHigh volume reticulated foam coalescer insert (for Class 1 BS EN 858 compliant separators) with long life and easy to maintain stainless steel basket.\u003c\/li\u003e\n\u003cli\u003eSo far in 2023 (up to the end of October 2023) SPEL have manufactured 100% of tanks on time so you can be confident you will get your tank on time with no delays or surprises!\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eSpill Capacity (litres):   7,600\u003c\/li\u003e\n\u003cli\u003eDrainage Area (m²):   1,111\u003c\/li\u003e\n\u003cli\u003eLength (mm):   4290\u003c\/li\u003e\n\u003cli\u003eDiameter (mm):   1825\u003c\/li\u003e\n\u003cli\u003eAccess Shaft (mm):   1no. 750mm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 9.10972%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\" width=\"36\" height=\"45\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 90.5293%;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/FP1C_SC-Customer.pdf?v=1701253829\" title=\"SPEL Puraceptor Full Retention Separator Drawing\" rel=\"noopener noreferrer\" target=\"_blank\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003eSPEL Puraceptor Full Retention Separator Drawing\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 9.10972%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\" width=\"36\" height=\"45\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 90.5293%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Section_13_Installation_c616daef-f2fc-4cd1-83ec-d175dae12578.pdf?v=1701253830\" title=\"Section 13 Installation\" rel=\"noopener noreferrer\" style=\"color: rgb(255, 128, 0);\" target=\"_blank\"\u003eSection 13 Installation\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 9.10972%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\" width=\"36\" height=\"45\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 90.5293%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/WARRANTY_25_Yr_2023.pdf?v=1700067089\" title=\"25 Year Warranty SPEL\" style=\"color: rgb(255, 128, 0);\" target=\"_blank\"\u003e25 Year \u003c\/a\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/WARRANTY_25_Yr_2023.pdf?v=1700067089\" title=\"25 Year Warranty SPEL\" style=\"color: rgb(255, 128, 0);\" target=\"_blank\"\u003eWarranty\u003c\/a\u003e \u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"SPEL","offers":[{"title":"Default Title","offer_id":40709773262937,"sku":"","price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/SPELPuraceptorFullRetentionForecourtSeparator.png?v=1700560819"},{"product_id":"klargester-aquatreat-full-retention-separator","title":"Klargester AquaTreat Full Retention Separator","description":"\u003cp style=\"text-align: left;\"\u003eThe Klargester AquaTreat range of water treatment separators help reduce pollution in line with SuDs Mitigation Indices by removing suspended solids and hydrocarbons from surface water. The surface water treatment range is suitable for a wide range of SuDs  schemes such as industrial estates, permitted sites and roadways. Mitigation Indices are available upon request. AquaTreat can cover drainage areas from 1,000-30,840m2 \u0026amp; are not suitable for use in applications that require EN 858 certification, as they are not oil separators.\u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e \u003c\/p\u003e\n\u003cp style=\"text-align: left;\"\u003e\u003cstrong\u003eProduct Features\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003eEasy servicing, with maintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLarger silt storage capacities (compared to vortex separators)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eDeep invert options available\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eLesser risk of downstream pollution in SuDs solution due to high capacity silt storage\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eMeets excellant SuDs indices ratings (compared to vortex separators) \u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eKlargester indices cater for high polluted lands (single piece solution)\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eSmartServ remote monitoring available for hassle free observance\u003c\/li\u003e\n\u003cli\u003eAquaTreat surface water (SWT) separators are not considered oil separators according to the EN858-1 standard and \u003cstrong\u003eMUST NOT\u003c\/strong\u003e be used in applications where full certification is required\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 99.4681%; height: 267.55px;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr style=\"height: 66.8875px;\"\u003e\n\u003ctd style=\"width: 10.5508%; height: 66.8875px;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"51\" width=\"41\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 89.2346%; height: 66.8875px;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca style=\"color: rgb(255, 128, 0);\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/kingspan-klargester-aquatreat-data-sheet-en-gb.pdf?v=1675335592\" title=\"Klargester Aquatreat Brochure\" target=\"_blank\"\u003e Klargester AquaTreat Brochure \u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 66.8875px;\"\u003e\n\u003ctd style=\"width: 10.5508%; height: 66.8875px;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"51\" width=\"41\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 89.2346%; height: 66.8875px;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca style=\"color: rgb(255, 128, 0);\" rel=\"noopener noreferrer\" title=\"AquaTreat Installation Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/018478-02_AquaTreat_SWT001_-_SWT019_Stormwater_Treatment_Device_Installation_Operation_Guidelines.pdf?v=1677834926\" target=\"_blank\"\u003eAquaTreat Installation Guidelines\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 66.8875px;\"\u003e\n\u003ctd style=\"width: 10.5508%; height: 66.8875px;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"51\" width=\"41\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 89.2346%; height: 66.8875px;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca style=\"color: rgb(255, 128, 0);\" rel=\"noopener noreferrer\" title=\"AquaCore Range Brochure\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/C20.7977_KS_AquaCore_LaunchBrochure.pdf?v=1677835103\" target=\"_blank\"\u003eAquaCore Range Brochure\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr style=\"height: 66.8875px;\"\u003e\n\u003ctd style=\"width: 10.5508%; height: 66.8875px;\"\u003e\u003cimg style=\"display: block; margin-left: auto; margin-right: auto;\" height=\"51\" width=\"41\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 89.2346%; height: 66.8875px;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca style=\"color: rgb(255, 128, 0);\" rel=\"noopener noreferrer\" title=\"AquaTreat Extension Neck Drawing\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/DS1373P-01_AquaTreat_SWT_Stormwater_Treatment_Devices_Neck_Coalescer_Extension_Details.pdf?v=1677834926\" target=\"_blank\"\u003eAquaTreat Extension Neck Drawing\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Kingspan Klargester","offers":[{"title":"Default Title","offer_id":56667191869813,"sku":null,"price":0.0,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/products\/KlargesterAquaTreat.png?v=1677759413"}],"url":"https:\/\/direct-drainage.co.uk\/collections\/klargester-full-retention-separators.oembed?page=2","provider":"Direct Drainage","version":"1.0","type":"link"}