{"title":"Bypass Separators","description":"\u003cp\u003eBypass separators are high-efficiency oil and water treatment systems designed to manage surface water runoff in low to medium risk areas such as car parks, roads, and commercial developments. These separators treat everyday flow by removing hydrocarbons like oil and fuel, while allowing high stormwater surges to bypass the system for effective flood management. Manufactured from durable, corrosion-resistant materials, bypass separators deliver reliable performance, long service life, and minimal maintenance requirements. Ideal for sustainable drainage systems (SuDS), they provide a cost-effective solution for pollution control, environmental compliance, and efficient surface water management.\u003c\/p\u003e","products":[{"product_id":"klargester-nsbe025-bypass-separator-13890m2","title":"13,890m2 Clearwater Bypass Separator | NSBE025","description":"\u003cp\u003eThe\u003cstrong\u003e \u003c\/strong\u003eClearwater Bypass Separator NSBE025\u003cstrong\u003e \u003c\/strong\u003esuitable for areas up to 13,890 sq\/m. Bypass separators are used when it is considered an acceptable risk not to provide full treatment, for very high flows, and are used, for example, where the risk of a large spillage and heavy rainfall occurring at the same time is small, e.g. \u003cspan\u003eEnvironment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase either the \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0); text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/www.direct-drainage.co.uk\/collections\/darcy\/products\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\" title=\"darcy mains alarm\" style=\"color: rgb(255, 128, 0); text-decoration: underline;\"\u003eDarcy Mains Alarm\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e \u003c\/span\u003ewith this item, and it will be delivered with the separator ready to wire in.\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSurface car parks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoadways\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLightly contaminated commercial areas\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003eFeatures and Benefits\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLight and easy to install\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eInclusive of silt storage volume\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eFitted inlet\/outlet connectors\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cspan\u003eVent points within necks\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExtension access shafts for deep inverts\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance from ground level\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\n\u003cspan\u003eGRP or rotomoulded construction (rotomoulded for NSBP003, NSBP004 and NSBP006)\u003c\/span\u003e\u003cbr\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e\u003cstrong\u003eTo specify a nominal size bypass separator, the following information is needed\u003c\/strong\u003e:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThe calculated flow rate for the drainage area served. Our designs are based on the assumption that any interconnecting pipework fitted elsewhere on site does not impede flow into or out of the separator and that the flow is not pumped\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe drain invert inlet depth\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePipework type, size and orientation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 7.14544%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 92.4936%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Bypass-Separator-drawing-NSBE010-NSBE030.pdf?v=1640274997\" title=\"Klargester Kingspan Bypass Separator drawing NSBE010 - NSBE030\" style=\"color: rgb(255, 128, 0);\"\u003eClearwater Bypass Separator drawing – NSBE010-NSBE030\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 7.14544%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 92.4936%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e \u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Class-1-Bypass-Separator-Guidelines-NSBE010-NSBE125_796fbbbb-c373-46b0-82e4-17b59d18972b.pdf?v=1640275105\" title=\"NSBE010-NSBE125 Class 1 Bypass Separator  Installation \u0026amp; Maintenance Guidelines\" style=\"color: rgb(255, 128, 0);\"\u003eClearwater Bypass Separator Guidelines Class 1– NSBE010-NSBE125\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"160mm","offer_id":31777091584089,"sku":"TANSEPAKLA010","price":3599.1,"currency_code":"GBP","in_stock":true},{"title":"315mm","offer_id":31777091649625,"sku":"TANSEPAKLA010","price":3599.1,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/NSBE010_5112013c-7aba-408b-bf75-551a3710364d.jpg?v=1742294337"},{"product_id":"klargester-nsbe030-bypass-separator-16670m2","title":"16,670m2 Clearwater Bypass Separator | NSBE030","description":"\u003cp\u003e\u003cspan\u003eThe\u003cem\u003e\u003cstrong\u003e \u003c\/strong\u003e\u003c\/em\u003eClearwater Bypass Separator NSBE030 suitable for areas up to 16,670 sq\/m. Bypass separators are used when it is considered an acceptable risk not to provide full treatment, for very high flows, and are used, for example, where the risk of a large spillage and heavy rainfall occurring at the same time is small, e.g.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSurface car parks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoadways\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLightly contaminated commercial areas\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch4\u003e\u003cspan style=\"color: rgb(64, 64, 64);\"\u003eFeatures and Benefits\u003c\/span\u003e\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLight and easy to install\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInclusive of silt storage volume\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFitted inlet\/outlet connectors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVent points within necks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExtension access shafts for deep inverts\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance from ground level\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGRP or rotomoulded construction (rotomoulded for NSBP003, NSBP004 and NSBP006)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo specify a nominal size bypass separator, the following information is needed:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eThe calculated flow rate for the drainage area served. Our designs are based on the assumption that any interconnecting pipework fitted elsewhere on site does not impede flow into or out of the separator and that the flow is not pumped\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eThe drain invert inlet depth\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003ePipework type, size and orientation\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 7.14544%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 92.4936%;\"\u003e \u003ca title=\"Klargester Kingspan Bypass Separator drawing NSBE010 - NSBE030\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Bypass-Separator-drawing-NSBE010-NSBE030.pdf?v=1640274997\"\u003e\u003cspan style=\"color: #b45f06;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003eClearwater Bypass Separator drawing – NSBE010-NSBE030\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"160mm","offer_id":31777092960345,"sku":"TANSEPAKLA011","price":4337.62,"currency_code":"GBP","in_stock":true},{"title":"315mm","offer_id":31777093025881,"sku":"TANSEPAKLA011","price":4337.62,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/NSBE010_5112013c-7aba-408b-bf75-551a3710364d.jpg?v=1742294337"},{"product_id":"klargester-nsbp003-bypass-oil-separator-1670m2","title":"1670m2  Clearwater Bypass Separator | NSBP003","description":"\u003cp\u003eThe Clearwater NSBP003 Bypass Separator is for areas up to 1,670 sq\/m. This range of Bypass separators from Clearwater, provide the ideal solution for low risk floods – when there is little possibility of a combined heavy rainfall and large spillage.\u003c\/p\u003e\n\u003cp\u003eBypass separators are used when it is considered an acceptable risk not to provide full treatment, for very high flows, and are used, for example, where the risk of a large spillage and heavy rainfall occurring at the same time is small, e.g. Surface car parks, roadways, lightly contaminated commercial areas. Environment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase the\u003cspan\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.direct-drainage.co.uk\/collections\/darcy\/products\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\" title=\"Darcy Complete IP65 Mains Separator Alarm with High Oil Probe (Klargester\/Conder)\"\u003e\u003cspan\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003eDarcy Mains Alarm\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003c\/a\u003e alongside this item, and it will be delivered with the separator ready to wire in.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Each bypass separator design includes the necessary volume requirements for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil separation capacity\u003c\/li\u003e\n\u003cli\u003eOil storage volume\u003c\/li\u003e\n\u003cli\u003eSilt storage capacity\u003c\/li\u003e\n\u003cli\u003eCoalescer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDrainage Area (m²):   1670\u003c\/li\u003e\n\u003cli\u003eFlow (litres\/second):   3\u003c\/li\u003e\n\u003cli\u003eStorage Capacity – Silt (litres):   300\u003c\/li\u003e\n\u003cli\u003eStorage Capacity – Oil (litres):   45\u003c\/li\u003e\n\u003cli\u003eLength (mm):   1700\u003c\/li\u003e\n\u003cli\u003eDiameter (mm):   1350\u003c\/li\u003e\n\u003cli\u003eAccess Shaft (mm):   600\u003c\/li\u003e\n\u003cli\u003ePipework (mm):   160    (315mm available on request)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Features and Benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli style=\"text-align: left;\"\u003eLight and easy to install\u003c\/li\u003e\n\u003cli\u003eInclusive of silt storage volume\u003c\/li\u003e\n\u003cli\u003eFitted inlet\/outlet connectors\u003c\/li\u003e\n\u003cli\u003eVent points within necks\u003c\/li\u003e\n\u003cli\u003eExtension access shafts for deep inverts\u003c\/li\u003e\n\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\u003cli style=\"text-align: left;\"\u003eGRP or rotomoulded construction (rotomoulded for NSBP003, NSBP004 and NSBP006)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp style=\"text-align: left;\"\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 9.10972%;\"\u003e\u003cimg height=\"45\" width=\"36\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 90.5293%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca title=\"Klargester Kingspan Class 1 Bypass Separator drawing NSBP003-NSBP006\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Class-1-Bypass-Separator-drawing-NSBP003-NSBP006.pdf?v=1640271558\" style=\"color: rgb(255, 128, 0);\"\u003eClearwater Class 1 Bypass Separator Drawing - NSBP003 - NSBP006\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 9.10972%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003cimg height=\"45\" width=\"36\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\"\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 90.5293%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca title=\"Klargester Kingspan Plastic Bypass Separators Guidelines – NSBP003-NSBP006\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Plastic-Bypass-Separators-Guidelines-NSBP003-NSBP006.pdf?v=1640271558\" style=\"color: rgb(255, 128, 0);\"\u003eClearwater Plastic Bypass Separators Guidelines\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"160mm \/ No","offer_id":31777118748761,"sku":"TANSEPAKLA001","price":1012.65,"currency_code":"GBP","in_stock":true},{"title":"160mm \/ Yes","offer_id":56573798023541,"sku":null,"price":1351.28,"currency_code":"GBP","in_stock":true},{"title":"315mm \/ No","offer_id":31777118781529,"sku":"TANSEPAKLA002","price":1012.65,"currency_code":"GBP","in_stock":true},{"title":"315mm \/ Yes","offer_id":56573798056309,"sku":null,"price":1351.28,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/NSBP003.jpg?v=1758812885"},{"product_id":"klargester-nsbp004-bypass-oil-separator-2500m2","title":"2,500m2  Clearwater Bypass Separator | NSBP004","description":"\u003cp\u003eThe\u003cstrong\u003e\u003cem\u003e \u003c\/em\u003e\u003c\/strong\u003eClearwater NSBP004 Bypass Separator\u003cstrong\u003e \u003c\/strong\u003eis for areas up to 2,500 sq\/m. This range of Bypass separators from Clearwater , provide the ideal solution for low risk floods – when there is little possibility of a combined heavy rainfall and large spillage. Bypass separators are used when it is considered an acceptable risk not to provide full treatment, for very high flows, and are used, for example, where the risk of a large spillage and heavy rainfall occurring at the same time is small, e.g. Surface car parks, roadways, lightly contaminated commercial areas. Environment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase the \u003ca title=\"Darcy Complete IP65 Mains Separator Alarm with High Oil Probe (Klargester\/Conder)\" href=\"https:\/\/www.direct-drainage.co.uk\/collections\/darcy\/products\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 128, 0); text-decoration: underline;\"\u003eDarcy Mains Alarm\u003c\/span\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/a\u003e alongside this item, and it will be delivered with the separator ready to wire in.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eEach bypass separator design includes the necessary volume requirements for:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eOil separation capacity\u003c\/li\u003e\n\u003cli\u003eOil storage volume\u003c\/li\u003e\n\u003cli\u003eSilt storage capacity\u003c\/li\u003e\n\u003cli\u003eCoalescer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul\u003e\n\u003cul\u003e\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTo specify a nominal size bypass separator, the following information is needed:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe calculated flow rate for the drainage area served. Our designs are based on the assumption that any interconnecting pipework fitted elsewhere on site does not impede flow into or out of the separator and that the flow is not pumped.\u003c\/li\u003e\n\u003cli\u003eThe drain invert inlet depth\u003c\/li\u003e\n\u003cli\u003ePipework type, size and orientation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Clearwater Bypass Separator Specification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDrainage Area (m²):   2500\u003c\/li\u003e\n\u003cli\u003eFlow (litres\/second):   4.5\u003c\/li\u003e\n\u003cli\u003eStorage Capacity – Silt (litres):   450\u003c\/li\u003e\n\u003cli\u003eStorage Capacity – Oil (litres):   60\u003c\/li\u003e\n\u003cli\u003eLength (mm):   1700\u003c\/li\u003e\n\u003cli\u003eDiameter (mm):   1350\u003c\/li\u003e\n\u003cli\u003eAccess Shaft (mm):   600\u003c\/li\u003e\n\u003cli\u003ePipework (mm):   160    (315mm available on request)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003cstrong\u003eFeatures and Benefits of the Clearwater NSBP004 Bypass Separator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight and easy to install\u003c\/li\u003e\n\u003cli\u003eInclusive of silt storage volume\u003c\/li\u003e\n\u003cli\u003eFitted inlet\/outlet connectors\u003c\/li\u003e\n\u003cli\u003eVent points within necks\u003c\/li\u003e\n\u003cli\u003eExtension access shafts for deep inverts\u003c\/li\u003e\n\u003cli\u003eMaintenance from ground level\u003c\/li\u003e\n\u003cli\u003eGRP or rotomoulded construction (rotomoulded for NSBP003, NSBP004 and NSBP006)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable style=\"width: 100%;\" width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 5.98762%;\"\u003e\u003cimg height=\"40\" width=\"32\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 93.6514%;\"\u003e \u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Class-1-Bypass-Separator-drawing-NSBP003-NSBP006.pdf?v=1640271558\" title=\"Klargester Kingspan Class 1 Bypass Separator drawing NSBP003-NSBP006\" style=\"color: rgb(255, 128, 0);\"\u003eClearwater Class 1 Bypass Separator Drawing - NSBP003 - NSBP006\u003c\/a\u003e\u003ca style=\"color: rgb(255, 128, 0);\" title=\"Klargester-Kingspan-Full-Retention-Separator-drawing-NSFP003-NSFP006\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Full-Retention-Separator-drawing-NSFP003-NSFP006.pdf?v=1640276472\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 5.98762%;\"\u003e\u003cimg height=\"40\" width=\"32\" alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 93.6514%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Plastic-Bypass-Separators-Guidelines-NSBP003-NSBP006.pdf?v=1640271558\" title=\"Klargester Kingspan Plastic Bypass Separators Guidelines – NSBP003-NSBP006\" style=\"color: rgb(255, 128, 0);\"\u003eClearwater Plastic Bypass Separators Guidelines\u003c\/a\u003e\u003c\/span\u003e\u003ca style=\"color: rgb(255, 128, 0);\" title=\"Klargester-Kingspan-Plastic-Full-Retention-Separator-Guidelines-NSFP003-NSFP006\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Plastic-Full-Retention-Separator-Guidelines-NSFP003-NSFP006.pdf?v=1640276473\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"No \/ 160mm","offer_id":31777119174745,"sku":"TANSEPAKLA003","price":1097.58,"currency_code":"GBP","in_stock":true},{"title":"No \/ 315mm","offer_id":31777119207513,"sku":"TANSEPAKLA004","price":1097.58,"currency_code":"GBP","in_stock":true},{"title":"Yes \/ 160mm","offer_id":56573853008245,"sku":null,"price":1436.2,"currency_code":"GBP","in_stock":true},{"title":"Yes \/ 315mm","offer_id":56573853041013,"sku":null,"price":1436.2,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/NSBP003_48089726-719b-484c-bc2b-5824d5d0542e.jpg?v=1758812914"},{"product_id":"klargester-nsbe010-bypass-oil-separator-5560m2","title":"5560m2  Clearwater Bypass Separator | NSBE010","description":"\u003cp class=\"product_title entry-title\"\u003e\u003cspan style=\"color: #000000;\"\u003eThis is the \u003cstrong\u003e\u003cem\u003eClearwater Bypass Separator NSBE010\u003c\/em\u003e \u003c\/strong\u003eis suitable for areas up to 5,560 sq\/m. Bypass separators are used when it is considered an acceptable risk not to provide full treatment, for very high flows, and are used, for example, where the risk of a large spillage and heavy rainfall occurring at the same time is small, e.g.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eSurface car parks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eRoadways\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eLightly contaminated commercial areas\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Bypass-Separator-drawing-NSBE010-NSBE030.pdf?v=1640274997\" title=\"Klargester Kingspan Bypass Separator drawing NSBE010 - NSBE030\"\u003e\u003cspan style=\"color: #b45f06;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"36\" height=\"36\" data-mce-fragment=\"1\"\u003e Clearwater Bypass Separator drawing – NSBE010-NSBE030\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Class-1-Bypass-Separator-Guidelines-NSBE010-NSBE125_796fbbbb-c373-46b0-82e4-17b59d18972b.pdf?v=1640275105\" title=\"NSBE010-NSBE125 Class 1 Bypass Separator  Installation \u0026amp; Maintenance Guidelines\"\u003e\u003cspan style=\"color: #b45f06;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"36\" height=\"36\" data-mce-fragment=\"1\"\u003e Clearwater Bypass Separator Guidelines Class 1– NSBE010-NSBE125\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #b45f06;\"\u003e Clearwater Separator NSBE010 Alarm Options\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eEnvironment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase either the \u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/www.direct-drainage.co.uk\/collections\/darcy\/products\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\" title=\"darcy mains alarm\"\u003eDarcy Mains Alarm\u003c\/a\u003e \u003c\/span\u003ewith this item, and it will be delivered with the separator ready to wire in. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #d96e02;\"\u003e\u003cstrong\u003eClearwater\u003c\/strong\u003e\u003c\/span\u003e \u003cstrong\u003e\u003cspan style=\"color: #b45f06;\"\u003eSeparator NSBE010 Features and Benefits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eLight and easy to install\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eInclusive of silt storage volume\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eFitted inlet\/outlet connectors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eVent points within necks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eExtension access shafts for deep inverts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eMaintenance from ground level\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eGRP or rotomoulded construction (rotomoulded for NSBP003, NSBP004 and NSBP006)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cspan style=\"color: #000000;\"\u003eTo specify a nominal size bypass separator, the following information is needed: \u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThe calculated flow rate for the drainage area served. Our designs are based on the assumption that any interconnecting pipework fitted elsewhere on site does not impede flow into or out of the separator and that the flow is not pumped\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003eThe drain invert inlet depth\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan style=\"color: #000000;\"\u003ePipework type, size and orientation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Clearwater","offers":[{"title":"160mm \/ No","offer_id":31777119731801,"sku":"TANSEPAKLA007","price":1647.97,"currency_code":"GBP","in_stock":true},{"title":"160mm \/ Yes","offer_id":56574133010805,"sku":null,"price":1986.6,"currency_code":"GBP","in_stock":true},{"title":"315mm \/ No","offer_id":31777119764569,"sku":"TANSEPAKLA007","price":1647.97,"currency_code":"GBP","in_stock":true},{"title":"315mm \/ Yes","offer_id":56574133043573,"sku":null,"price":1986.6,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/NSBE010_5112013c-7aba-408b-bf75-551a3710364d.jpg?v=1742294337"},{"product_id":"klargester-nsbp006-bypass-oil-separator-3335m2","title":"3335m2  Clearwater Bypass Separator | NSBP006","description":"\u003cp data-mce-fragment=\"1\"\u003eThe \u003cstrong\u003e\u003cem\u003eClearwater\u003c\/em\u003e NSBP006 Bypass Separator \u003c\/strong\u003eis for areas up to 3,335 sq\/m. This range of Bypass separators from Clearwater, provide the ideal solution for low risk floods – when there is little possibility of a combined heavy rainfall and large spillage.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003eBypass separators are used when it is considered an acceptable risk not to provide full treatment, for very high flows, and are used, for example, where the risk of a large spillage and heavy rainfall occurring at the same time is small, e.g. Surface car parks, roadways, lightly contaminated commercial areas.\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca title=\"Klargester Kingspan Class 1 Bypass Separator drawing NSBP003-NSBP006\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Class-1-Bypass-Separator-drawing-NSBP003-NSBP006.pdf?v=1640271558\" data-mce-fragment=\"1\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"40\" height=\"40\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e Clearwater Class 1 Bypass Separator Drawing - NSBP003 - NSBP006\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003ca title=\"Klargester Kingspan Plastic Bypass Separators Guidelines – NSBP003-NSBP006\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Plastic-Bypass-Separators-Guidelines-NSBP003-NSBP006.pdf?v=1640271558\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003e\u003cimg height=\"40\" width=\"40\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" alt=\"\" data-mce-fragment=\"1\"\u003e Clearwater Plastic Bypass Separators Guidelines\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e Each bypass separator design includes the necessary volume requirements for:\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOil separation capacity\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eOil storage volume\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eSilt storage capacity\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eCoalescer\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eBypass Separator Alarm Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEnvironment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase the\u003cspan data-mce-fragment=\"1\"\u003e \u003c\/span\u003e\u003ca href=\"https:\/\/www.direct-drainage.co.uk\/collections\/darcy\/products\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\" title=\"Darcy Complete IP65 Mains Separator Alarm with High Oil Probe (Klargester\/Conder)\" data-mce-fragment=\"1\"\u003e\u003cspan data-mce-fragment=\"1\"\u003eDarcy Mains Alarm\u003c\/span\u003e\u003c\/a\u003e alongside this item, and it will be delivered with the separator ready to wire in.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e Clearwater Bypass Separator Specification\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eDrainage Area (m²):   3335\u003cbr\u003eFlow (litres\/second):   6\u003cbr\u003eStorage Capacity – Silt (litres):   600\u003cbr\u003eStorage Capacity – Oil (litres):   90\u003c\/p\u003e\n\u003cp\u003eLength (mm):   1700\u003cbr\u003eDiameter (mm):   1350\u003cbr\u003eAccess Shaft (mm):   600\u003cbr\u003ePipework (mm):   160    (315mm available on request)\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eFeatures and Benefits of the Clearwater NSBP006 Bypass Separator\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eLight and easy to install\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eInclusive of silt storage volume\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eFitted inlet\/outlet connectors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eVent points within necks\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eExtension access shafts for deep inverts\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eMaintenance from ground level\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cul data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eGRP or rotomoulded construction (rotomoulded for NSBP003, NSBP004 and NSBP006)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr data-mce-fragment=\"1\"\u003e\u003c\/p\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cstrong\u003eTo specify a nominal size bypass separator, the following information is needed:\u003c\/strong\u003e\u003c\/p\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003col data-mce-fragment=\"1\"\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThe calculated flow rate for the drainage area served. Our designs are based on the assumption that any interconnecting pipework fitted elsewhere on site does not impede flow into or out of the separator and that the flow is not pumped.\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003eThe drain invert inlet depth\u003c\/li\u003e\n\u003cli data-mce-fragment=\"1\"\u003ePipework type, size and orientation.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/ol\u003e\n\u003cp data-mce-fragment=\"1\"\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"160mm \/ No","offer_id":31777119961177,"sku":"TANSEPAKLA005","price":1199.7,"currency_code":"GBP","in_stock":true},{"title":"160mm \/ Yes","offer_id":56573935780213,"sku":null,"price":1538.33,"currency_code":"GBP","in_stock":true},{"title":"315mm \/ No","offer_id":31777119993945,"sku":"TANSEPAKLA006","price":1199.7,"currency_code":"GBP","in_stock":true},{"title":"315mm \/ Yes","offer_id":56573935812981,"sku":null,"price":1538.33,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/NSBP003_5ac68383-333f-4895-a373-7cf4cde07813.jpg?v=1758812934"},{"product_id":"klargester-nsbe015-bypass-oil-separator-8335m2","title":"8335m2 Clearwater Bypass Separator | NSBE015","description":"\u003cp class=\"product_title entry-title\"\u003e\u003cspan\u003eThe \u003cem\u003e\u003cstrong\u003eClearwater\u003c\/strong\u003e\u003c\/em\u003e \u003cem\u003e\u003cstrong\u003eBypass Separator NSBE015\u003c\/strong\u003e\u003c\/em\u003e is suitable for areas up to 8,335 sq\/m. Bypass separators are used when it is considered an acceptable risk not to provide full treatment, for very high flows, and are used, for example, where the risk of a large spillage and heavy rainfall occurring at the same time is small, e.g.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eSurface car parks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eRoadways\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLightly contaminated commercial areas\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Bypass-Separator-drawing-NSBE010-NSBE030.pdf?v=1640274997\" title=\"Klargester Kingspan Bypass Separator drawing NSBE010 - NSBE030\"\u003e\u003cspan style=\"color: #b45f06;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"36\" height=\"36\" data-mce-fragment=\"1\"\u003e Clearwater Bypass Separator drawing – NSBE010-NSBE030\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Class-1-Bypass-Separator-Guidelines-NSBE010-NSBE125_796fbbbb-c373-46b0-82e4-17b59d18972b.pdf?v=1640275105\" title=\"NSBE010-NSBE125 Class 1 Bypass Separator  Installation \u0026amp; Maintenance Guidelines\"\u003e\u003cspan style=\"color: #b45f06;\"\u003e\u003cimg alt=\"\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/pdf_480x480.png?v=1595254149\" width=\"36\" height=\"36\" data-mce-fragment=\"1\"\u003e Clearwater Bypass Separator Guidelines Class 1– NSBE010-NSBE125\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #b45f06;\"\u003eClearwater Separator NSBE015 Alarm Options\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEnvironment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase either the \u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/www.direct-drainage.co.uk\/collections\/darcy\/products\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\" title=\"darcy mains alarm\"\u003eDarcy Mains Alarm\u003c\/a\u003e \u003c\/span\u003ewith this item, and it will be delivered with the separator ready to wire in.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cspan style=\"color: #b45f06;\"\u003e Clearwater Separator NSBE015 Features and Benefits\u003c\/span\u003e\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eLight and easy to install\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eInclusive of silt storage volume\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eFitted inlet\/outlet connectors\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eVent points within necks\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eExtension access shafts for deep inverts\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eMaintenance from ground level\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eGRP or rotomoulded construction (rotomoulded for NSBP003, NSBP004 and NSBP006)\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003cspan\u003eTo specify a nominal size bypass separator, the following information is needed:\u003c\/span\u003e\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe calculated flow rate for the drainage area served. Our designs are based on the assumption that any interconnecting pipework fitted elsewhere on site does not impede flow into or out of the separator and that the flow is not pumped\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003eThe drain invert inlet depth\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cspan\u003ePipework type, size and orientation\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Clearwater","offers":[{"title":"160mm \/ No","offer_id":31777120157785,"sku":"TANSEPAKLA008","price":2256.43,"currency_code":"GBP","in_stock":true},{"title":"160mm \/ Yes","offer_id":56574181015925,"sku":null,"price":2595.05,"currency_code":"GBP","in_stock":true},{"title":"315mm \/ No","offer_id":31777120190553,"sku":"TANSEPAKLA008","price":2256.43,"currency_code":"GBP","in_stock":true},{"title":"315mm \/ Yes","offer_id":56574181048693,"sku":null,"price":2595.05,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/NSBE010_5112013c-7aba-408b-bf75-551a3710364d.jpg?v=1742294337"},{"product_id":"klargester-nsbe020-bypass-oil-separator-11111m2","title":"11111m2 Clearwater Bypass Separator | NSBE020","description":"\u003cp class=\"product_title entry-title\"\u003e\u003cspan\u003eThe\u003cstrong\u003e \u003c\/strong\u003eClearwater\u003cem\u003e \u003c\/em\u003eBypass Separator NSBE020 is suitable for areas up to 11,111 sq\/m. Bypass separators are used when it is considered an acceptable risk not to provide full treatment, for very high flows, and are used, for example, where the risk of a large spillage and heavy rainfall occurring at the same time is small, e.g.\u003c\/span\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eSurface car parks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eRoadways\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eLightly contaminated commercial areas\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eEnvironment Agency PPG3 Guidelines stipulate that all separators must be fitted with a robust system to provide an audible and visual alarm if the oil level becomes too high. We strongly recommend that you purchase either the \u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0); text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca title=\"darcy mains alarm\" href=\"https:\/\/www.direct-drainage.co.uk\/collections\/darcy\/products\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\" style=\"color: rgb(255, 128, 0); text-decoration: underline;\"\u003eDarcy Mains Alarm\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca title=\"darcy mains alarm\" href=\"https:\/\/www.direct-drainage.co.uk\/collections\/darcy\/products\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\" style=\"color: rgb(255, 128, 0); text-decoration: underline;\"\u003e \u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0); text-decoration: underline;\"\u003e\u003cstrong\u003e\u003ca title=\"darcy mains alarm\" href=\"https:\/\/www.direct-drainage.co.uk\/collections\/darcy\/products\/darcy-mains-separator-alarm-with-high-oil-probe-klargester-conder\" style=\"color: rgb(255, 128, 0); text-decoration: underline;\"\u003e\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/span\u003ewith this item, and it will be delivered with the separator ready to wire in.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003eBenefits\u003c\/strong\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cspan\u003eLight and easy to install\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eInclusive of silt storage volume\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eFitted inlet\/outlet connectors\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eVent points within necks\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eExtension access shafts for deep inverts\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eMaintenance from ground level\u003c\/span\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cspan\u003eGRP or rotomoulded construction (rotomoulded for NSBP003, NSBP004 and NSBP006)\u003c\/span\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ctable width=\"100%\" style=\"width: 100%;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10.7169%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\" width=\"44\" height=\"55\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88.9221%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca title=\"NSBE010-NSBE125 Class 1 Bypass Separator  Installation \u0026amp; Maintenance Guidelines\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Class-1-Bypass-Separator-Guidelines-NSBE010-NSBE125_796fbbbb-c373-46b0-82e4-17b59d18972b.pdf?v=1640275105\" style=\"color: rgb(255, 128, 0);\"\u003eClearwater Bypass Separator Guidelines Class 1– NSBE010-NSBE125\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 10.7169%;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/direct_drainage_PDF_icon_c37d6f6e-3727-4654-bc65-f5da7e818096.png?v=1727870404\" alt=\"\" width=\"44\" height=\"55\"\u003e\u003c\/td\u003e\n\u003ctd style=\"width: 88.9221%;\"\u003e\u003cspan style=\"color: rgb(255, 128, 0);\"\u003e\u003cstrong\u003e\u003ca title=\"Klargester Kingspan Bypass Separator drawing NSBE010 - NSBE030\" href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/Klargester-Kingspan-Bypass-Separator-drawing-NSBE010-NSBE030.pdf?v=1640274997\" style=\"color: rgb(255, 128, 0);\"\u003eClearwater Bypass Separator drawing – NSBE010-NSBE030\u003c\/a\u003e\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003ePLEASE CONTACT US FOR AN ACCURATE LEAD TIME\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"color: #fa8315;\"\u003e\u003cb\u003esales@direct-drainage.co.uk\u003c\/b\u003e\u003c\/span\u003e\u003c\/p\u003e","brand":"Clearwater","offers":[{"title":"160mm \/ No","offer_id":31777120419929,"sku":"TANSEPAKLA009","price":2761.68,"currency_code":"GBP","in_stock":true},{"title":"160mm \/ Yes","offer_id":56574264934773,"sku":null,"price":3100.3,"currency_code":"GBP","in_stock":true},{"title":"315mm \/ No","offer_id":31777120452697,"sku":"TANSEPAKLA009","price":2761.68,"currency_code":"GBP","in_stock":true},{"title":"315mm \/ Yes","offer_id":56574264967541,"sku":null,"price":3100.3,"currency_code":"GBP","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/files\/NSBE010_5112013c-7aba-408b-bf75-551a3710364d.jpg?v=1742294337"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0269\/2035\/3881\/collections\/bypass.jpg?v=1778165354","url":"https:\/\/direct-drainage.co.uk\/collections\/bypass-separators.oembed","provider":"Direct Drainage","version":"1.0","type":"link"}